| Specification | Details |
| Cooling Capacity | 8.7–90 kW |
| Operable Ambient Temperature | 5°C to 50°C |
| Operable Liquid Temperature | 10°C to 30°C |
| Control Precision | ±0.5°C; up to ±0.1°C under stable load conditions |
| Compressor | Inverter-Driven Scroll Type |
| Condenser | Finned Tube, Forced Air Cooling |
| Control Method | Inverter Drive |
| Evaporator | SUS316 Plate-Type, Copper Brazed |
| Discharge Pump | Multistage Centrifugal, SS Body & Impeller |
| Refrigerant | R410A |
| Power Supply | 3 Phase, 400V ±5%, 50Hz |
| Water Tank | Approx. 44–320 L, model dependent |
| Communication | RS485 |
| Parallel Connection | Up to 12 modules |
An inverter chiller continuously adjusts its cooling output to match the actual heat load of the connected process.
Step 1 – Heat Load Detection
The system monitors process temperature and cooling demand.
Step 2 – Compressor Speed Adjustment
The inverter controls compressor speed according to the required cooling capacity.
Step 3 – Refrigerant Circulation
The refrigeration circuit removes heat from the process liquid.
Step 4 – Heat Rejection
The condenser transfers the extracted heat to the surrounding air.
Step 5 – Cooled Liquid Delivery
The chilled liquid is circulated back to the connected equipment.
Step 6 – Continuous Modulation
The compressor speed changes as the process load rises or falls, avoiding unnecessary full-load operation.
Precise Temperature Control
Variable-speed operation enables highly stable cooling, with control precision of approximately ±0.1°C possible under stable load conditions.
Lower Energy Consumption
The compressor adjusts its output to the actual cooling requirement instead of continuously operating at full capacity.
Reduced Start-Stop Cycling
Variable-speed operation minimizes frequent compressor starts and stops, supporting smoother operation and reduced mechanical stress
.
Efficient Scroll Compressor
Inverter-driven hermetically sealed scroll compressor technology provides efficient and reliable cooling performance.
Durable Heat Exchanger
The plate-type evaporator uses SUS316 construction with copper brazing for reliable heat transfer and durability.
High-Pressure Pumping
The integrated stainless steel multistage pump can support applications requiring higher water pressure, with configurations available up to 6 bar / 60 m head.
Wide Operating Conditions
The system is designed for liquid temperatures from 10°C to 30°C and ambient temperatures from 5°C to 50°C.
Smart Connectivity
RS485 communication, remote ON/OFF and potential-free status contacts facilitate integration with industrial control systems
The inverter chiller range can be configured with features suited to different industrial cooling requirements.
Core Features
Configuration Options
Oil-Injected, Rotary Screw Compressor
Oil-Injected, Rotary Screw Compressor
Oil-Injected, Rotary Screw Compressor
Oil-Injected, Rotary Screw Compressor